Effect of Operation Time on the Performance and Accuracy of the Condor Reflectometer
DOI:
https://doi.org/10.52825/solarpaces.v2i.931Keywords:
Device Accuracy, Operation Lifetime, ReproducibilityAbstract
This paper evaluates the potential effect that operation lifetime could have on the accuracy and reproducibility of the Condor reflectometer. For this purpose, three Condors with different operation lifetimes have been used and compared in this study. In addition to the device’s operation lifetimes, reproducibility and the repeatability of the measurements have also been evaluated. Silvered glass mirrors at different states have been used, e.g., clean, soiled and eroded in order to evaluate the effect of the surface properties on the difference reported using different devices. The obtained results have shown that the difference in specular reflectance reported by the three different Condors is more noticeable in case of soiled and eroded glass mirrors compared to clean sample. This could be linked to the surface roughness more than to the years of operation of the device itself.
Downloads
References
[1] C.Sansom, A.F.Garcia, P.King, F.Sutter, A.G.Segura, Solar Energy, 155 (2017) 496-505, doi: https://doi.org/10.1016/j.solener.2017.06.053
[2] A.F.García, F.Sutter, L.M.Arcos, C.Sansom, F.Wolfertstetter, C.Delord, Solar Energy Materials and Solar Cells, 167 (2017) 28-52, doi: https://doi.org/10.1016/j.solmat.2017.03.036
Published
How to Cite
Conference Proceedings Volume
Section
License
Copyright (c) 2024 Mounia Karim, Christopher Sansom, Zaharaddeen Hussaini, Heather Almond, Aránzazu Fernández-García, Florian Sutter, Florian Wiesinger, Johannes Wette, Peter King
This work is licensed under a Creative Commons Attribution 4.0 International License.
Accepted 2024-09-06