The centrifugal particle receiver (CentRec®) developed by DLR for high-temperature solar applications, previously tested on sun in a 500 kWth prototype at the solar tower in Jülich was further developed and tested at slightly smaller scale of 300 kWth. The test with artificial sunlight provided more stationary and controllable boundary conditions. Outlet temperature of 681 °C was reached at an irradiating input power of 214 kW. The performance was determined with particle mass flow and temperature measurement systems. The data confirms the thermodynamic model for this receiver, indicating an extrapolated performance of 81% at nominal conditions.

Downloads

Download data is not yet available.

References

W. Wu, L. Amsbeck, R. Buck, R. Uhlig, R. Ritz-Paal, “Proof of concept test of a centrifugal particle receiver”, SolarPACES 2013, Las Vegas, USA (2013). Doi: https://doi.org/10.1016/j.egypro.2014.03.060

M. Ebert, L. Amsbeck, A. Jensch, J. Hertel, J. Rheinländer, D. Trebing, R. Uhlig, R. Buck, “Upscaling, Manufacturing and Test of a Centrifugal Particle Receiver“, Proceedings of the ASME 2016 10th International Conference on Energy Sustainability, ES2016-59252 (2016). Doi: https://doi.org/10.1115/ES2016-59252

M. Ebert, L. Amsbeck, R. Buck, J. Rheinländer, B. Schloegl, S. Schmitz, M. Sibum, R. Uhlig, “Operational Experience of a Centrifugal Particle Receiver Prototype”, SolarPACES 2018, AIP Conference Proceedings, Casablanca, Morocco (2018). Doi: https://doi.org/10.1063/1.5117530

L. Amsbeck, M. Ebert, B. Gobereit, J. Hertel, A. Jensch, J. Rheinländer, D. Trebing, R. Uhlig, “First tests of a centrifugal particle receiver with a 1m² aperture”, 23rd International Conference on Concentrating Solar Power and Chemical Energy Systems, SolarPACES 2017, 2033 (040004), Santiago de Chile (2017). Doi: https://doi.org/10.1063/1.5067040

Hall, B. D. "Evaluating methods of calculating measurement uncertainty." Metrologia 45.2 (2008): L5. Doi: https://doi.org/10.1088/0026-1394/45/2/N01

C. Frantz, M. Ebert, L. Amsbeck, “Experimental Evaluation of the Thermo-Optical Efficiency of a Centrifugal Particle Receiver”, ASME 2019 - 13th International Conference on Energy Sustainability ES 2019, Phoenix, AZ, USA.

M. Ebert, M. Lubkoll, R. Buck, J. Hertel, S. Zunft, G. Iaquaniello, B. Masciocchi, A. Salladini, L. Alfieri, L. Ruini, C. Detaille, M. Smolders, A. Guillick, X. Mas, S. Costa, D. Akcura, L. Amsbeck, W. Wu, W. Schewtschenko, “Detail Engineering of a High Storage Density Solar Power Plant for Flexible Energy Systems”, SolarPACES 2021.

K. Wieghardt, D. Laaber, V. Dohmen, P. Hilger, D. Korber, K.H. Funken, B. Hoffschmidt, Bernhard (2018) Synlight - A New Facility for Large-Scale Testing in CSP and Solar Chemistry. In: 23rd International Conference on Concentrating Solar Power and Chemical Energy Systems, SolarPACES 2017, 2033 (040042), 23rd SolarPACES Conference, Santiago de Chile (2017). Doi: https://doi.org/10.1063/1.5067078